Cold Cathode germicidal lamps are instant starting and utilize a large cylindrical cathode instead of a tungsten filament. Due to this construction, the lamp is not adversely affected by frequent starting and the life is considerably in excess of other lamp types. STER-L-RAY® Cold Cathode germicidal lamps have favorable operating characteristics at reduced temperatures. They are, therefore, widely used in walk-in refrigerators and holding rooms.
Cold Cathode germicidal lamps are well suited to disinfection of air and surfaces of unoccupied areas due to their long life and low depreciation. Cold cathode germicidal lamps are also employed in applications where frequent starting is a requirement. Available in ozone producing and non-ozone producing versions
Lamp Description | Length (mm)Base
Face to Base Face |
Lamp
Watts 1 |
Approx
Lamp Current mA |
Ultraviolet Output |
Ozone
Output if applicable 4 |
Rated
Effective Life (hrs) |
||
Ozone
Free |
Ozone
Producing |
Total
Watts 2 |
Microwatts
@ 1 meter 3 |
|||||
CC12T5L | CC12T5VH | 230 | 15 | 90 | 2.8 | 22 | 0.4 | 20,000 |
782L10 | 782VH10 | 357 | 20 | 90 | 2.9 | 29 | 0.8 | 20,000 |
CC18T5L | CC18T5VH | 381 | 21 | 90 | 3.2 | 32 | 0.8 | 20,000 |
CC24T5L | CC24T5VH | 538 | 23 | 90 | 5.0 | 47 | 1.3 | 20,000 |
782L20 | 782VH20 | 611 | 24 | 90 | 5.8 | 55 | 1.5 | 20,000 |
CC36T5L | CC36T5VH | 843 | 28 | 90 | 8.5 | 75 | 2.3 | 20,000 |
782L30 | 782VH30 | 865 | 29 | 90 | 8.7 | 77 | 2.3 | 20,000 |
CC48T5L | CC48T5VH | 1148 | 34 | 90 | 11.2 | 98 | 3.0 | 20,000 |
1 Wattage is lamp watts only and does not include ballast loss.
|