Product Description

Cold Cathode germicidal lamps are instant starting and utilize a large cylindrical cathode instead of a tungsten filament. Due to this construction, the lamp is not adversely affected by frequent starting and the life is considerably in excess of other lamp types. STER-L-RAY® Cold Cathode germicidal lamps have favorable operating characteristics at reduced temperatures. They are, therefore, widely used in walk-in refrigerators and holding rooms.

Cold Cathode germicidal lamps are well suited to disinfection of air and surfaces of unoccupied areas due to their long life and low depreciation. Cold cathode germicidal lamps are also employed in applications where frequent starting is a requirement. Available in ozone producing and non-ozone producing versions

Lamp Description Length (mm)Base
Face to Base Face
Lamp
Watts
1
Approx
Lamp
Current mA

Ultraviolet Output

Ozone
Output
if applicable
4
Rated
Effective
Life
(hrs)
Ozone
Free
Ozone
Producing
Total
Watts
2
Microwatts
@ 1 meter

3
CC12T5L CC12T5VH 230 15 90 2.8 22 0.4 20,000
782L10 782VH10 357 20 90 2.9 29 0.8 20,000
CC18T5L CC18T5VH 381 21 90 3.2 32 0.8 20,000
CC24T5L CC24T5VH 538 23 90 5.0 47 1.3 20,000
782L20 782VH20 611 24 90 5.8 55 1.5 20,000
CC36T5L CC36T5VH 843 28 90 8.5 75 2.3 20,000
782L30 782VH30 865 29 90 8.7 77 2.3 20,000
CC48T5L CC48T5VH 1148 34 90 11.2 98 3.0 20,000

1 Wattage is lamp watts only and does not include ballast loss.
2 Ultraviolet output at 254 nanometers at 100 hours and 80ºF (approximate).
3 Microwatts per square centimeter at one meter from lamp.
4 Approximate ozone output in grams per hour under favorable conditions. Figures apply only to ozone producing types. Please note that ozone output is subject to considerable variation due to conditions under which the lamp is used; under many conditions, the ozone output may be only a fraction of the specified figure.
---
Please note that ozone output is subject to considerable variation due to conditions under which the lamp is used; under many conditions, the ozone output may be only a fraction of the specified figure.