Product Description

UV AIR PURIFYING SYSTEM

          DO IT AT HOME BY YOURSELF ,IT IS EASY INSTALLATION AND WELL DONE

 

MODEL: UV-201212 , UV-201213UV-201218,UV-201236UV-2012357UV-2012406UV-201225S

UV AIR LIGHTS FOR HVAC OR HOME AIR PURIFIER

MODEL.

VOLTS

WATTS

0.5HZ/0.6HZ

UV OUTPUT 1 Meter

REMARKS

UV-2012357

120V

20W

0.5HZ/0.6HZ

83

 RECOMMEND

UV-201225S

120V

18W

0.5HZ/0.6HZ

72

 RECOMMEND

UV-201236

120V

40W

0.5HZ/0.6HZ

170

 

UV-201224

120V

24W

0.5HZ/0.6HZ

120

 

UV-201218

120V

20W

0.5HZ/0.6HZ

80

 RECOMMEND

UV-201213

120V

13W

0.5HZ/0.6HZ

60

 RECOMMEND

UV-2012-2H36

120V

72W

0.5HZ/0.6HZ

350

 

UV-2012008

120V

20W

0.5HZ/0.6HZ

83

 

UV-2012009-2S18

120V

36W

0.5HZ/0.6HZ

200

 

UV-2012012

120V

12W

0.5HZ/0.6HZ

75

STRONG RECOMMEND

20%OZONE 80%FREE

 

UV-C light inhibits the growth and reproduction of germs and bacteria that circulate through a home’s heating and air conditioning system. The treatment is a safe, silent, and proven way to make your home a healthier place to live.

 

The UV-PURE unit is designed to emit powerful UVC band light rays which sterilize and reduce airborne  microorganisms as they pass through a heating or air conditioning system. It is installed in the main supply or return duct and operates continuously to automatically purify the air in the home 24 hours a day.

 

This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or condition nor for use in the mitigation, treatment, or prevention of any disease or condition.

 

READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

 

This device MUST be installed by a qualified agency in accordance with the manufacturer's installation instructions. The definition of a qualified agency is: any individual, firm, corporation or company which either in person or through a representative is engaged in, and is responsible for, the installation and operation of HVAC appliances, who is experienced in such work, familiar with all the precautions required, and has complied with all the requirements of the authority having jurisdiction.

 

SAFETY CONSIDERATIONS

 

WARNING: Before installing or servicing a humidifier, air filter, heat system, or this unit, etc., always turn

all power OFF and have units unplugged. Electrical shock can cause personal injury or death. Never

expose eyes or skin to direct UV-C light from any source.

WARNING: To prevent water damage or electric shock, do not mount unit under a humidifier.

WARNING: Designed for a closed duct system. Do not mount near a return air opening.

WARNING: This product is designed for indoor installation only (i.e. attics, crawl spaces, basements,

etc.). For use on gas fired, oil fired, electric and split system heat pump forced air systems*. This product

is NOT designed to be mounted outside on gas fired or heat pump packaged units**.

WARNING: Never expose eyes or skin to UVC light from any source.

• Looking directly at the UVC light may cause permanent eye damage or blindness.

• Never operate the UV-PURE Air Purifying System out of the plenum.

• Designed for a closed duct system. Do not mount near a supply or a return air opening.

• All duct openings in direct line of site of the UV light must be sealed with aluminum tape or equivalent sealing methods.

WARNING: UV light will break down plastic materials not rated for UV exposure:

(Examples: wire insulation, flex duct, drain pans and humidifiers)

• The unit must be mounted at least 30" from the above stated type of materials.

• I f it is necessary to mount the unit in direct line of sight of these types of materials, they must be shielded with aluminum foil, aluminum foil tape, or sheet metal.

WARNING: DO NOT mount this unit outdoors.

• This product is designed for indoor installation only (i.e. attics, crawl spaces, basements, etc.).

 

WARNING: Never touch broken lamp or internal contents of lamp. The lamp contains mercury.

• After opening the carton, unpack and inspect the unit and lamp for damage. Do not install

 this unit if any damage is noticeable. If lamp is damaged, cracked or broken, do not touch

lamp or other contents in carton. Close carton and return to seller immediately.

• In case of accidental exposure to internal contents of lamp, wash hands and any other

affected skin area with mild detergent. Remove affected clothing immediately. If skin surface

 is pierced, seek medical attention immediately.

NOTE: If you touch the glass of the lamp, you should wipe the glass clean with isopropyl alcohol

and a lint free wipe. If the lamp is not cleaned, the film of hand oils causes a reduction in the

light intensity.

WARNING: Before installing or servicing a humidifier, air filter, HVAC system, or this unit, etc.,

always turn all power OFF and have unit unplugged. Electrical shock can cause personal injury or

death. Never expose eyes or skin to direct UVC light from any source.

WARNING: To prevent water damage or electric shock, do not mount unit under a humidifier.

WARNING: This product is designed for indoor installation only (i.e. attics, crawl spaces, basements,

etc.). For use on gas fired, oil fired, electric and split system heat pump forced air systems*. This

product is NOT designed to be mounted outside on gas fired or heat pump packaged units**.

 

WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness.

Never operate the UV-PURE Air Purifying System out of the plenum.

 Avoid touching the glass portion of the lamp with your hands

 

GENERAL INFORMATION

The UV-PURE unit uses technology that is recommended by doctors who state that “ultraviolet radiation,properly integrated with heating, ventilating, and air conditioning systems, shows the most promise as a widely applicable means of air disinfection”.

 

 

INSTALLATION

1. Locate a suitable location for the unit

downstream from the 'A' coil in the supply

plenum or in the return plenum; preferably

downstream from the air filter. For optimum

"cleaning" effect on the 'A' coil, mount the

unit in the supply plenum as close as possible

to the 'A' coil. (See Figure 1)

 

 

 

 

IF YOU HAVE FLEX DUCT

For installations on duct systems with a metallic main duct and flex duct branches, follow the instructions in figure below.

 

 

 

 

EASY INSTALLATION STEP:

1.    Measure the decide where and measure the hole of the wall to check the size if it is

suitable To install the unit.

2.    Insert the uv bulb into the socket .see the Figure.

3.    Mount the unit base to the duct using the four mounting screws provided. See Figure

4.    Replace cover on unit.Tighten top side screws and down side screws.

5.    Flip switch on box to the ON position.( Light on switch should be on)

6.    Look through view port in the box cover on the left to be sure the lamp is working.

You can see a blue light. (we have a lens in the hole and blocks the UVC rays)

 

 

Industry Accepted Kill Chart

Organisms:

Energy dosage of Ultraviolet radiation in µW sec/cm2 needed for kill factor 

Bacteria

90%

100%

Bacillus anthracis - Anthrax

4,520

8,700

Bacillus anthracis spores - Anthrax spores

24,320

46,200